60KW IGBT Based Accurate Variable DC Power Supply
Get Latest PricePayment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air |
Port: | SHANGHAI,NANJING,QINGDAO |
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air |
Port: | SHANGHAI,NANJING,QINGDAO |
Model No.: MTP - 60KW
Brand: IDEALTEKNIC
Output Power: ≫500w
Input Voltage: Three-Phase, Four-Wire 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Circuit Mode: Full-Bridge Phase-Shifting Soft Switch Pwm Regulation
Working Mode: Constant Voltage / Constant Current
Display Mode: Lcd
Control Mode: Lcd Touch Screen
Protections: Ovp, Ocp, Otp And Short Circuit Protections.
Applications: Lab, Motor Test, Battery Charging, Inverter Test
Certifications: Ce
Cooling: Forced Air Cooling
Selling Units | : | Piece/Pieces |
Package Type | : | Plywood case |
Picture Example | : | |
Download | : |
The file is encrypted. Please fill in the following information to continue accessing it
MTP Series High Power DC Power Supply
Overview
The 45 ~ 60KW DC Power Supplies in the MTP series high-power DC power supply family are built with 600*1700*800 industrial-grade cabinets, with casters at the bottom, or floor-standing cabinets without casters. The output voltage ranges from 100Vdc to 1000Vdc. The Power Supplies’ control panel adopts a 7-inch LCD touch screen for power supplies’ control programming and status monitoring, and also comes with the standard RS485 communication interface following the MODBUS-RTU international protocol makes remote control and monitoring of the High-power Power Supplies easy and convenient.
This series of high-power AC DC Power Supplies adopt the AC/DC power processing topology of iDeal-Electronics full-bridge phase-shifting soft-switching technology and optimized design of reliable two-stage conversion mechanism control and drive logic circuit.
Our high power AC/DC power supplies achieve the balance between output low ripple and fast response speed requirements for High-power Switching Power Supplies by the required matching parameters of transformer, inductance, and LC which can be quickly calculated through the company’s internal design table, so that this series of high-power DC Switching Power Supplies can provide high precision, low ripple, and high stable high-power DC output with maintaining the unique fast response speed of the switching power supply.
The 45 ~60KW High Power DC Power Supplies also have the short-term 2 times rated current overload capacity equipped with all MTP series DC power supplies (except for some large current output models).
At present, this series of High Power DC power supplies are mainly used in battery charging testing, DC motor testing, photovoltaic inverter testing, and various cutting-edge applications that require high-power DC output.
Features
l Isolated input and output for safe operation.
l CV & CC output mode, output voltage and current continuously adjustable in full scale.
l Multi-stage filtering circuit adopted to reduce harmonic interference to the power grid.
l Double closed-loop circuit, fast response speed and stable output.
l Full-bridge phase-shifting soft switching technology, the overall efficiency is up to 88%.
l With RS485 communication interface, in line with MODBUS-RTU communication protocol.
l With LCD touch screen for convenient operation, intuitive displays & indications.
l Amorphous high-frequency transformers and potted inductance adopted to give smaller temperature rise and better reliability.
l The input and output terminals are equipped with safety shielding to ensure the safety of installation.
Principle Introduction
Key Technology Introduction
Air duct design
Full-sealing independent "Chimney" type air duct design adopted, the inner circuit uses independent cooling fan to improve the product heat dissipation effect, and the air inlet has dustproof measures, which greatly reduces dust and debris entering the power supply. The radiator and fan can be cleaned and maintained separately
The heat dissipation system undergoes rigorous simulation and actual testing, and is designed with reliability in consideration of national standards and enterprise standards to ensure that the device with low temperature rise and long life.
l Ambient temperature: Please have the power source working in safe temperature range (0℃ ~ 45℃) or it would affect life of power source.
l Please install the power source at least 50cm distant from surroundings to have better ventilation.
l Please install the power source away from vibration (less than 0.6G), especially equipment like puncher.
l Keep the power source away from direct sunshine, humidity or place with water globule.
l Keep the power source from corrosive, flammable & explosive gas.
l Keep the power source away from oil stain, dust & metallic dust.
CV / OC with 2 times overload ability (except for models with ≥ 500A) |
The power supply has two working modes: CV / CC mode and CV / OC mode, customers can select different working modes according to actual use requirements. (1). CV / CC mode Under CV / CC mode, the output voltage and current of power supply are continuously adjustable from 0 to the rated value. Power supply works either in constant voltage (CV) or constant current (CC) state, the CV & CC working state are automatically switchable, the switching conditions are determined by the voltage & current set values and the customer's load resistance value. For details, please refer to the following figure. In CV state, the output voltage is adjustable and regulated; the output current varies with the output voltage value and the customer load resistance. In CC state, the output current is adjustable and regulated, the output voltage varies with the output current value and the customer load resistance.
(2). CV / OC mode Under CV / OC (over current) mode, besides CV function, power supply still has over-current working ability, (OCP is invalid in this mode), detailed parameters as below: 0% ~ 100% rated current value è continuous working with load 100% ~ 125% rated current value è withstand 600s continuous working 125% ~ 150% rated current value è withstand 60s continuous working 150% ~ 200% rated current value è withstand 5s continuous working Power supply automatic protected and stops output when Max. Over-current time exceeded. |
LCD touch screen operation / display function |
The power supply adopts LCD touch screen for output parameters setting, working status and alarm information monitoring. The LCD screen has memory function which can automatically save the power failure occurrence time and fault phenomenon for easy query in real time. Also, the touch screen has lock screen function, which can automatically lock screen when the operation is not performed for a long time. Thereby preventing the wrong operation from changing the power output state by mistake. |
OVP & OCP value setting function |
OVP and OCP value could be set via front control interface, power supply could automatically stop output when output voltage or output current exceeds the set protection values. OVP: over voltage protection value. OCP: over current protection value. |
Automatic line voltage drop compensation function |
The power supply has an automatic line voltage drop compensation detection terminal (comsense). Connect the terminals to the load ends. The power supply will automatically detect the voltage value of the load ends and automatically compensate for the line voltage drop caused by the power line. At the same time, it can be customized to detect whether the battery terminals are connected reversely to realize the anti-reverse protection function for battery charging. |
Fast self-discharge function |
The power supply has built-in discharging circuit, which can quickly release the electrical energy in the output capacitor after the power supply stops outputting, so as to prevent personal injury caused by accidently touching the output terminal right after the power supply stops. |
Short-circuit protection |
The power supply can adapt to two kinds of short-circuit conditions as below: If the power supply has short-circuited before starting output, then power supply can be normally started and running continuously for a long time. If power supply has a sudden short-circuit during running with load, then power supply would automatically stop output and gives sound alarm, LEDs on front panel would display corresponding alarm code. |
Input |
Connection mode |
Three – phase, four – wire + GND |
||
Voltage |
380V±10% |
|||
Frequency |
50Hz/60Hz±5Hz |
|||
Output |
Rated power |
** kW |
||
Output voltage adjusting range |
0V ~ ****V |
|||
Output current adjusting range |
0A ~ ***A |
|||
Output voltage precision |
0.5%FS |
|||
Output current precision |
0.5%FS |
|||
Line regulation |
≤0.2%FS |
|||
Load regulation |
≤0.2%FS |
|||
Temperature drift |
0.04%FS/℃ |
|||
Time drift |
0.3%FS |
|||
Ripple (Vr.m.s.) |
≤0.5% F.S (measured @ rated voltage with 80%-100% resistive loading) |
|||
Response time |
≤20ms (measured @ 10%-90% resistive loading) |
|||
Efficiency |
≥88% (measured @ 80%-100% resistive loading) |
|||
Working ability |
Withstand long-term continual working. |
|||
Setting & Display |
Control mode |
Local |
Front panel LCD touch screen. |
|
Remote |
RS485 communication interface. In line with MODBUS-RTU standard. |
|||
Display mode |
Touch screen display items as below: 1. Real-time working state display (fault state, running state, stop state, emergency stop state) 2. Working mode display (CV / CC) 3. Output voltage / current display. 4. Power supply system and fault information queriable. |
|||
Set & Display error |
Voltage |
0.5%FS |
||
Current |
0.5%FS |
|||
Display resolution |
Voltage |
Four-digit display with a minimum resolution of 0.01V (Ue ≤ 30V) |
||
Four-digit display with a minimum resolution of 0.1V (30V < Ue < 1000V) |
||||
Four-digit display with a minimum resolution of 1V (Ue ≥ 1000V) |
||||
Current |
Four-digit display with a minimum resolution of 0.01A (Ie ≤ 50A) |
|||
Four-digit display with a minimum resolution of 0.1A (50A < Ie < 1000A) |
||||
Four-digit display with a minimum resolution of 1A (Ie ≥ 1000A) |
||||
Automatic voltage compensation |
≤5V (Ue ≤ 100V) |
|||
≤10V (100V<Ue ≤ 300V) |
||||
≤15V (300V< Ue ≤ 1000V) |
||||
Over-loading ability |
Iout≤1.25 Ie, output shutdown after 600s. Iout≤1.5Ie, output shutdown after 60s. Iout≤2Ie, output shutdown after 5s Iout>2Ie, output shutdown immediately. |
|||
Protection & Monitoring functions |
Output over voltage protection (OVP) |
Output over voltage protection value settable. Power supply automatically cuts off output and alarms when output has over voltage. |
||
Output over current protection (OCP) |
Output over current protection value settable. Power supply automatically cuts off output and alarms when the output has over current. |
|||
Over temperature protection (OTP) |
Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds 85 °C. |
|||
Output short-circuit protection |
Power supply automatically cuts off output and alarms when the output has short-circuit. |
|||
Automatic voltage compensation protection |
Output over compensation protection / compensation line reverse-connected protection |
|||
Noise |
≤65dB |
|||
Protection degree |
IP20 |
|||
Cooling method |
Forced air cooling |
|||
Safety features |
Insulation resistance |
≥20MΩ |
||
Withstand voltage ability |
60s test @ 2000VDC, no flash-over or spark-over. |
|||
Grounding inductance resistance |
≤100mΩ |
|||
Working conditions |
Ambient temperature |
0℃~45℃ |
||
Humidity |
10%~90%(non-condensing) |
|||
Height |
≤2000m |
|||
|
Model |
MTP-0100-0500T |
MTP-0150-0333T |
MTP-0200-0250T |
MTP-0300-0167T |
MTP-0600-0085T |
MTP-1000-0050T |
Rated power |
50KW |
|||||
Rated voltage |
100.0V |
150.0V |
200.0V |
300.0V |
600.0V |
1000V |
Rated current |
500.0A |
333.0A |
250.0A |
167.0A |
85.0A |
50.00A |
Model |
MTP-0100-0500T |
MTP-0150-0400T |
MTP-0200-0300T |
MTP-0300-0200T |
MTP-0600-0100T |
MTP-1000-0060T |
Rated power |
60KW |
|||||
Rated voltage |
100.0V |
150.0V |
200.0V |
300.0V |
600.0V |
1000V |
Rated current |
600.0A |
400.0A |
300.0A |
200.0A |
100.0A |
60.0A |
l Analog control via 0 ~ 5V / 0 ~ 10V or 4mA ~ 20mA signal. (+AC)
l Output power-limiting function (+PL)
l Built-in automatic energy discharging unit (+EDU)
l 24V interlock circuit (+ILK)Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.